Thứ Hai, 17 tháng 9, 2018

PR-6000 Tokyo KeiKi Vietnam

PR-6000 Tokyo KeiKi Vietnam, PR-6000 Tokyo KeiKi Viet nam , PR-6000 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam

This high-grade autopilot model was designed with three fundamental concepts in mind: expanding and strengthening helm functions, thorough safety considerations, and improved reliability and more intelligent maintenance functions.
  • IBS (Integrated Bridge System) compatibility
  • Improved interface
  • Complete range of controls
  • Compatible with a variety of steering systems
  • Safety considerations designed in
  • Standard compatibility with digital output gyros

PR-2000 Tokyo KeiKi Vietnam

PR-2000 Tokyo KeiKi VietnamPR-2000 Tokyo KeiKi Viet namPR-2000 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam

This best-selling model has been installed in over 15,000 small and medium vessels including fishing boats, coastal craft, and merchant ships, and is renowned for its stable performance and ease of use.
  • Designed for operational simplicity
  • More affordable, with improved course holding ability
  • Variety of system configurations (stand-alone model, GYLOT model, console model)
  • Compatible with a variety of steering systems
 "GYLOT" is a registered trademark of TOKYO KEIKI.

TMG-30 Tokyo KeiKi Vietnam

TMG-30 Tokyo KeiKi VietnamTMG-30 Tokyo KeiKi Viet namTMG-30 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam



Optimal machine operation based on gyrocompass attitude navigational information
In excavation of complicated and interconnected underground tunnels for subways, water lines, and communication and power lines, accuracy in following plan lines is vital. Development of the new TMG-30 Series attitude sensing system for tunnel boring machinery is based on our experience on more than 1800 site applications and our expertise in advanced technology. The System's precision gyrocompass and servo-inclinometer offer real-time detection of azimuth angle, pitch & roll with stable attitude readouts. The small, lightweight and high precision, TMG-30 Series is a valuable aid in tunnel excavations, both large and small.

Features

  • Small size, high accuracy
    Compared to our previous model, the sensor unit is approx. 30% smaller and the controller and power supply are approx. 70% smaller. Static accuracy is ± 0.05 deg.
  • Real-time monitoring of machinery attitude
    Azimuth angle and pitch & roll can be displayed in real time, for continuous monitoring and accurate control of machinery movement.
  • Efficiency
    Unlike laser and lightwave systems, there is no need for time-wasting resetting.
  • Backup battery
    The backup battery assures continuous operation even in the event of a power supply failure.
  • Monitoring
    With the easy-to-read monitor, communication errors, and other information is at your fingertips.
  • System expansion
    Efficient excavation and accurate monitoring can be enhanced in combination with the TL300 Series Level sensing System and the Tellus Series Automated Position & Attitude-sensing System.

UFH-100 Tokyo KeiKi Vietnam

UFH-100 Tokyo KeiKi VietnamUFH-100 Tokyo KeiKi Viet namUFH-100 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam
 
looking for a highly accurate and reliable flow metering system? Check out the UFH-100!
Microwave level gauge is included as standard equipment!

UFH-100 flowmeter measures free surface flows of such fluids as...
Typical Applications 
・Supply water ・Agrigultural water
・River water ・Waste water
・process water ・industrial effuents

The TOKYO KEIKI UFH-100 ultrasonic flowmeter system for open channels employs the latest in ultrasonic and microwave technology.
Utilizing our wealth of know-how and technical expertise, the UFH-100 system combines an ultrasonic flow rate meter with a microwave level gauge to provide accurate and stable flowmeasurements.
It is applicable for liquids with free surfaces such as agricultural water, river water, waste water and industrial effluents.

Specifications
Measurable liquidApplications: agricultural water, river water, process water, industrial effluents, etc.
Water temperature: 0~40℃ /Turbidity: ≤ 10000 mg/L (degree)
Measurement water channelWater channel width: 0.3~20m (circular water channels φ0.3~5m)
Needed channel straight run: standard - upstream ≥ 10B, downstream ≥ 5B
(B: water channel width, pipe diameter in case of circular water channel)
Measurement principleFlow: flow velocity x channel cross sectional area (water level) computation method
Flow velocity: ultrasonic pulse transit time difference method
Water level s from existing or any 2 wire level gauge (DC 4~20mA can be utilized
Measurement rangeFlow: 0~full water level flowFlow velocity: 0~10m/sWater level: 0~10m
Output signalsFlow: 4~20 mA DC (allowable load resistance within 750Ω) with arrester element
Flow Pulse: Capacity AC 3~250V / DC 3~125V
Flow velocity: 4~20 mA DC (option: allowable load resistance within 750Ω)
Water level 4~20 mA DC (option: allowable load resistance within 750Ω)
AccuracyFlow     Forward flow: less than ±3% of full scale
            Reverse flow: not specified as it depends on channel structure
(+/- 10mm or better accuracy for level gauge required.)
Alarm relay outputWater level measurement failure, flow velocity measurement failure
Display16 digit x 16 digit LCD display (with backlight)
Flow value: max. 6 digits (incl. comma, decimal point)
Water level: max. 6 digits (incl. m unit, comma and decimal point)
Flow velocity: max. 6 digits (including m/s unit, comma and decimal point)
Operation status indication 
Power sourceAC90V - 132V (50/60 ±2Hz)   Standard
AC180V - 250V (50/60 ±2Hz)   (Option)
Power consumptionAC100V approx. 30VA
AC240V approx. 40VA
Ambient temperature -10C degree ~ 50C degree
Ambient humidityLess than 90% RH (non-condensation)
Main unit configurationWall mount type IP5X (IEC60529 / dust proof)
WeightApprox. 10 kg (approx. 11 kg with ultrasonic water level gauge)

UFP-20 Tokyo KeiKi Vietnam

UFP-20 Tokyo KeiKi VietnamUFP-20 Tokyo KeiKi Viet namUFP-20 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam


Portable Ultrasonic Flowmeter UFP-20 Now Comes, Versatility ! Functionality ! Reliability !
The Portable Ultrasonic Flowmeter UFP-20, based on the same, ergonomically advanced design so popular in the UFP-10, features significant size reduction. The result is a portable ultrasonic flowmeter that meets next-generation standards.The UFP-20's single-handed portability means difficult and challenging jobs located in narrow or high places can now be performed safely and easily.

The flowmeter includes a thickness measurement function and can effectively measure the sound velocity of fluids. Measurement data can be printed, logged or transferred to a computer which can assist data collection and analysis.

Light Weight - 1.4 kg
Wide Display and Easy Operation
Pipe Range : 13 - 5000 mm
Transducer can use : -20 - +120C degree
Weather-proof structure : IP65




Multi-Flow Measurement Function
Easy configurable for 2-Channel or 2-Path measurement



2-channel:Multi-flow measurement

2-path:Higher Stability




Energy Meter Function
Energy flow rate measurements with Pt100 RTD option.


Receiving-Echo Monitor Function
Visual confirmation that receiving echo is “good”.

Weather-proof structure IP65
IP65 rating maintained even during measurement.

USB Memory Data Transfer
Logged data and site conditions can be storaged into internal memory.


Language selection
You can choose
English, French, German, Italian,Japanese, Portuguese, Russian, Spanish, and Turkish.



Example of flowmeter or massmeter basic system




Example of heatmeter basic system



UFH-100 Tokyo KeiKi Vietnam

UFH-100 Tokyo KeiKi VietnamUFH-100 Tokyo KeiKi Viet namUFH-100 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam

looking for a highly accurate and reliable flow metering system? Check out the UFH-100!
Microwave level gauge is included as standard equipment!

UFH-100 flowmeter measures free surface flows of such fluids as...
Typical Applications 
・Supply water ・Agrigultural water
・River water ・Waste water
・process water ・industrial effuents

The TOKYO KEIKI UFH-100 ultrasonic flowmeter system for open channels employs the latest in ultrasonic and microwave technology.
Utilizing our wealth of know-how and technical expertise, the UFH-100 system combines an ultrasonic flow rate meter with a microwave level gauge to provide accurate and stable flowmeasurements.
It is applicable for liquids with free surfaces such as agricultural water, river water, waste water and industrial effluents.

Specifications
Measurable liquid
Applications: agricultural water, river water, process water, industrial effluents, etc.
Water temperature: 0~40℃ /Turbidity: ≤ 10000 mg/L (degree)

Measurement water channel
Water channel width: 0.3~20m (circular water channels φ0.3~5m)
Needed channel straight run: standard - upstream ≥ 10B, downstream ≥ 5B
(B: water channel width, pipe diameter in case of circular water channel)

Measurement principle
Flow: flow velocity x channel cross sectional area (water level) computation method
Flow velocity: ultrasonic pulse transit time difference method
Water level s from existing or any 2 wire level gauge (DC 4~20mA can be utilized

Measurement range
Flow: 0~full water level flow
Flow velocity: 0~10m/s
Water level: 0~10m
Output signals
Flow: 4~20 mA DC (allowable load resistance within 750Ω) with arrester element
Flow Pulse: Capacity AC 3~250V / DC 3~125V
Flow velocity: 4~20 mA DC (option: allowable load resistance within 750Ω)
Water level 4~20 mA DC (option: allowable load resistance within 750Ω)

Accuracy
Flow     Forward flow: less than ±3% of full scale
            Reverse flow: not specified as it depends on channel structure
(+/- 10mm or better accuracy for level gauge required.)

Alarm relay output
Water level measurement failure, flow velocity measurement failure
Display
16 digit x 16 digit LCD display (with backlight)
Flow value: max. 6 digits (incl. comma, decimal point)
Water level: max. 6 digits (incl. m unit, comma and decimal point)
Flow velocity: max. 6 digits (including m/s unit, comma and decimal point)
Operation status indication 

Power source
AC90V - 132V (50/60 ±2Hz)   Standard
AC180V - 250V (50/60 ±2Hz)   (Option)

Power consumption
AC100V approx. 30VA
AC240V approx. 40VA

Ambient temperature
 -10C degree ~ 50C degree
Ambient humidity
Less than 90% RH (non-condensation)
Main unit configuration
Wall mount type IP5X (IEC60529 / dust proof)
Weight
Approx. 10 kg (approx. 11 kg with ultrasonic water level gauge)

Chủ Nhật, 16 tháng 9, 2018


UVH-2000 Tokyo KeiKi Vietnam,  UVH-2000 Tokyo KeiKi Viet nam ,  UVH-2000 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam

Doppler Technology For Sewage, Wastewater or Industrial Effluents.
Accurate and stable flow measurements for open channels with Ultrasonic Pulse Doppler technology. The UVH-2000 measures velocity of flow which contain fine particles or slurries such as sewage and wastewater

The UVH-2000 flowmeter incorporates a velocity meter and level gauge to measure flows through pipes or open channels with free water surfaces of sewage, wastewater, industrial and other effluents containing fine particles, sludge or fine bubbles.
The UVH-2000 velocity meter employs Pulse Doppler technology, which provides flow velocities at multi-points on the ultrasound beam and an ultrasonic level gauge, which provides non-contact liquid level measurement.
The UVH-2000 is suitable for applications such as maintenance and flow management of industrial effluents, public utilities, sewage plants and sewage systems.

Specifications
Measurement MethodFlow velocity: Ultrasonic Pulse Doppler
Fluid level: Ultrasonic Pulse Transit Time
FluidsSewage, waste water, Industrial Effluents, or other Fluids with suspended matters Fluids or small bubbles which reflect ultrasonic waves with a free water surface (turbidity, approx. 60~50,000 mg/L)
Fluid Temperature0 ~ +40℃
Applicable open ChannelOpen channels: Rectangular, Circular, etc. Closed Conduit
 Dimensions of Circular type: Inner diameter φ250 ~ 5000mm
 Dimensions of Rectangular. Width 250 ~ 5000mm
Measurement RangeFlow velocity: -5 ~ +5 m/s
Water level: 0 ~ 5000 mm
Measurement AccuracyWithin ±3% of Full Scale
Main Unit DisplayLCD: 16 x 16 Characters
Displayed items: Flow rate/ Totalized Flow/ Flow Velocity/ Water Level,
                 Measurement Units. and Functions (at configuration) 
Power SupplyAC90 ~ 132V, 180 ~ 264V, DC19 ~ 29V
Power ConsumptionApprox. 38VA (AC100V), approx. 58VA (AC240), Approx. 24W (DC24V) 
Output SignalsFlow Rate: 4 ~ 20 mA   DC (allowable resistance: less than 750Ω)
Totalized Flow: Photo MOS Relay (Insulated)
Flow Velocity: 4 ~ 20 mA    DC (allowable resistance: less than 750Ω)
Water Level: 4 ~ 20 mA    DC (allowable resistance: less than 750Ω)
Flow Velocity Meter Malfunction Warning: Photo MOS Relay (Insulated)
Level Gauge Malfunction Warning: Photo MOS Relay (Insulated)
Forward Flow Reverse Flow Discrimination: Photo MOS Relay (Insulated)
Ambient Temperature -10 ~ +50℃.
Ambient HumidityLess than 90% RH (non-condensation)
Main Unit WeightApprox. 16kg
Main Unit DimensionsW332 x H520 x D170 (including mounting bracket)
OptionsMulti Path Flow Velocity Measurement: Max. 4 Paths
Level Measurement: Radar Level Gauge

KRG-10 Tokyo KeiKi Vietnam


KRG-10 Tokyo KeiKi VietnamKRG-10 Tokyo KeiKi Viet nam KRG-10 Tokyo KeiKi ,  KRG-10
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam


Non - Contacting Radar Level Gauge KRG-10 Now Comes,
Measurement Unlimited By the Imagination.

The KRG-10 measures liquid level by transmitting low energy radar pulses towarda liquid surface and receiving the radar echoes.
The travel time for the radar pulse is proportional to the distance between the gauge and the surface.

Features

±2mm High Accuracy
Advanced Echo Processing
Rapid Tracking
Flow & Volume Calculation
Wide Lin-Up for various applications
Explosion - proof
Intrinsically safe

Target Market

Petro - chemical
Fine - chemical
Pharmaceutical
Food
General industrial
Water distribution
Factory effluent

Specifications

General SpecificationFrequency26GHz
Beam Angle8°(4inch Cone antenna & PTFE Sealing antenna)
18°(2inch Cone antenna & PTFE Sealing antenna)
25°(1inch Rod antenna)
MeasurementMAX range30m
AccuracyCone & PTFE Sealing ±2mm
Rod±3mm 
Repeatability±1mm
Interval1s
Tracking rate2m / sec max.
Display 5 digits LCD / 4 keys-menu-driven
Level, Distance, Volume(Flow), Current, Signal strength selectable
Power Supply Signal OutputPower Supply (Loop-Powered)DC10.5V ~ 36V (In case of Ex, the voltage is rated separately.)
Signal Output4 ~ 20mA + HART
AlarmHold, 22mA or 3.6mA selectable
Ambient Temperature -40 ~ 70℃ (Non-Ex) / -40 ~ +60℃ (Ex)
Mechanical SpecificationTank Pressure1.5MPa
Tank Temperature -40 ~ 200℃
IP ClassIP66, NEMA4X
ATEXEN60079-0:2012
EN60079-1:2007
EN60079-11:2012
EN60079-26:2007
EN60079-31:2009
Ex ia
II 1G Ex ia IIC T4 Ga Ta = -40℃ to +60℃, IP66
II 1D Ex ia IIIC T135℃ Da Ta = -40℃ to +60℃, IP66
Ex d ia
II 1/2G Ex d ia IIC T4 Gb / Ga Ta = = -40℃ to +60℃, IP66
(PTFE Sealing Antenna and Rod Antenna)
II 2G Ex d ia IIC T4 Gb Ta = -40℃ to +60℃, IP66
(Cone Antenna)
IECExIEC 60079-0:2011
IEC 60079-1:2006
IEC 60079-11:2011
IEC 60079-26:2006
IEC 60079-31:2008
Ex ia
Ex ia IIC T4 Ga Ta = -40℃ to +60℃, IP66
Ex ia IIIC T135℃ Da Ta = -40℃ to +60℃, IP66
Ex d ia
Ex d ia IIC T4 Gb / Ga Ta = = -40℃ to +60℃, IP66
(PTFE Sealing Antenna and Rod Antenna)
Ex d ia IIC T4 Gb Ta = -40℃ to +60℃, IP66
(Cone Antenna)
Function  - Multi-echo historical validation    - Disturbance noise elimination     - Distance filter window
 - Bottom echo handler                - Double bounce handler             - Full-range search mode
 - Volume calculation                   - Predict Output                        - Flow rate calculation (Weir / Flume)

MRG-10 Tokyo KeiKi Vietnam

MRG-10 Tokyo KeiKi VietnamMRG-10 Tokyo KeiKi Viet namMRG-10 Tokyo KeiKi ,
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam


The MRG-10 measures liquid level by transmitting low energy radar pulses toward a liquid surface and receiving the radar echoes.
The radar pulse is virtually unaffected by the contents and atmosphere of the tank, temperature or pressure. Thus radar measurement is proven to be the most reliable gauging method in most applications. Furthermore, maintenance requirements are practically zero because no part of the gauge is in physical contact with the liquid.
These features make the MRG-10 very well suited for storage and buffer tanks in the chemical and water industry.

The MRG-10 is most appropriate for calm liquid surfaces. If you intend to use the MRG-10 to measure turbulent surface liquids, it may be recommended to employ a still pipe used in order to achieve a calm surface.

The MRG-10 is appropriate for storage tanks or buffer tanks that have relatively calm surfaces.

  • Chemical and petroleum
  • Pharmaceuticals
  • Food and beverage
Other applications include:
  • Industrial water such as river intake gates
  • Water supply
  • Sewage water treatment plant
  • Hydraulic power station


♦Application Examples

Opne conduits
Tanks with turbulent surfaces

Specifications
1. General
Measuring principleTime Flight impulse Radar technology
Operating frequency6 GHz
Half power beam angleRod antenna: 30deg.,   Cone antenna 4": 34deg., 6": 22deg.,  8": 17deg.
Microwave output powerMax 1 μ W
Reference conditionsFree space reflection from metal surface, ambient temperature 25℃, atmospheric pressure
2.Display / Configuration
Local display 5 digit LCD display with 4 configuration buttons. Level, Ullage, Volume, Current or Amplitude output
HART hand held communicatorRosemount communicator RS275, just display not for configuration
PC Remote configurationWindows base setup and configuration software
3 Electrical
Power supplyLoop powered 16-36 VDC (16-30VDC in Ex applications)
OutputAnalog DC4-20mA +HART
Output variableLevel, Ullage in m or ft. Volume in %, Amplitude in dB.
Signal on alarmHold, Low (3.9mA), High (22mA)
Cable entry 2-M20x1.5(Applicable Cable diameter : 6.5-9.0mm)
4. Mechanical
Antenna Rod antenna, Cone antenna 4", 6", 8" 
Antenna material exposed to tankRod antenna: PFA and SUS(316L,ext.version)
Cone antenna: 4", 6", 8" SUS(316L), PTFE, Viton
Antenna dimensionSee page 5 and 6
Housing / Enclosure Casting Aluminum
FlangeOn request or customer supply
Mass3.3--4.3Kg, depend on antenna size
Height above flange230 mm
5. Environment Condition
Max. pressure10 bar. (145 psi) 
Ambient temperature -20 ℃ to 70 ℃ (-4°F to 158°F), LCD Display -20 ℃ to 70 ℃
Storage temperature -40 ℃ to 80 ℃ (-40°F to 176°F)
Tank inside temperature -20 ℃ to 150 ℃ (-4°F to 302°F)
Ingress protection IP65
Vibration resistanceIEC 68-2-6/1G
Ex. ApprovalTIIS Ex ia IIC T4
6 Measuring Performance
Instrument accuracy +/- 10mm
Repeatability +/- 1mm
Update interval1 Second
Measuring rangeDepend on Antenna type and products nature, see diagram at page 4

MRF-10 Tokyo KeiKi Vietnam


MRF-10 Tokyo KeiKi VietnamMRF-10 Tokyo KeiKi Viet namMRF-10 Tokyo KeiKi MRF-10
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam
 
Features
  1. IP68 submergible
    Stormwater will not break MRF-10 by under the water.
  2. Compact body (Height: 54mm)
    Height: 54mm, easy installation for narrow space like under the Manhole
  3. Loop-Powered
    Easy replacement to existing Loop-powered instrumentations
  4. HART communication
    HART protocol has been superimposed onto analog output
  5. Easy Configuration
    Graphical PC software by HART
  6. Simple one-piece structure
    No independent main console required
Specifications
GeneralMeasuring principleTime of Flight Impulse Radar Technology
Operating frequency5.8GHz
Half power beam angleLengthwise: 50°/ Crosswise: 23°
Display /ConfigurationNo display / Graphical PC Configuration available
ElectricalPower supplyLoop-powered 16 ~ 36V DC
OutputAnalog: 4-20mA + Digital: HART Protocol
Output variableLevel,  Ullage (m or ft), Volume(%), Amplitude (dB)
Signal on alarmHold, Low (3.9mA), High (22mA)
OthersArrester and 10m shielded twisted 3 - cores Cable are built-in.
MechanicalHousing (Enclosure)Body: Casting stainless steel (316 equivalent)/Antenna face: FRP
Size172 x 192 x 54mm (without Cable gland)
MassApprox. 2.7kg (without Cable)
EnvironmentAmbient temperature -20℃ ~ 70℃ (-4°F ~ 158°F)
Ambient pressureATM
Protection degreeIEC 60529 IP68 (10m Depth /24hr.)
Measuring PerformanceAccuracy±5mm (0.1 - 5m range)
±10mm (5 - 10m range)
Repeatability±1mm
Update interval1sec
Measuring rangeUp to 10m Max.
Applicable circular channel: more than φ400mm

VD-10 Tokyo KeiKi Vietnam


VD-10 Tokyo KeiKi Vietnam,  VD-10 Tokyo KeiKi Viet nam ,  VD-10 Tokyo KeiKi ,
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam , TOKYO-KEIKI VIETNAM , TOKYO-KEIKI
 
OVERVIEW
The Vibration Detector is a safety device, which quickly detects abnormalities in mechanical equipment in order to help prevent breakdown.
The reliable performance of the Vibration Switch is time proven - it has received very favorable user response from the time it was first marketed over 30 years ago.

Specification
TypeStandard
Model  VD-10
RangeSetting range 0 ~ 44.1m/s2 (0 ~ 4.5G)
Recommended range 4.9 ~ 44.1m/s2 (0.5 ~ 4.5G)
Resolution 0.98m/s2 (0.1G)
Frequency range0 ~ 300Hz
Accuracy +/- 2.21m/s2
OutputForm Relay output
Contact formS.P.D.T.
Capacity125/250V AC (3A)
48V DC (1A)
125V DC (0.5A)
250V DC (0.25A)
ResetOperationManual reset : Reset button operation
Remote reset: Remote reset by power supply
Reset power100 ~ 125V AC/DC (50/60Hz in AC power)
Coil rating100V AC/DC (5min)
110V AC/DC (3min)
115V AC/DC (2.5min)
125V AC/DC (2min)
Rated current 0.23A
Power consumption25VA
Environmental
Condition
Temperature -20C deg ~ +80C deg
Humidity10 ~ 95% RH (non-condensation)
ConstructionProtection degree IPX4 (JIS C 0920)
Ex-approvalNot approved
Cable connectionRc3/4 (PT3/4)
Case materialMount; Aluminum casting (AC4C)
Cover ; Aluminum alloy plate (A5052)
ColorHammer tone Baked (N7)
Mass Approx. 0.9Kg

DL-3000 Tokyo KeiKi Vietnam


DL-3000 Tokyo KeiKi Vietnam, DL-3000 Tokyo KeiKi Viet nam , DL-3000 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam

Features
  • Wide capability for various ship
    Laser of DL-3000 system targets against parallel part at the ship board and
    achieve stable measurement even for shallow drafted ship.
  • Compliance with safety class
    Laser sensor is complied with safety standard JIS C 6802 class 1.
  • Vivid-visuality
    Measured data is vividly displayed and also can be output as record data.
  • Fully-functioned alarm system
    Variety of alarms such as over-speed alarm, ripping alarm and
    berthing angle alarm has been functioned for berthing support as safely.
  • Variety option
    DL-3000 system can extend and connect with further option such as large
    display for vessel, Signal lamp alert, data telemetering etc.
ItemDescription
Measuring item Distance between Bow to Berth and Stern to Berth
Measuring method Lase Pulse Echo
Measuring range Distance : -1 ~ 199m
 Speed : 0~+/-99 cm/sec (+: Docking / -: Ripping)
 Angle coverage : less than +/-15 deg.
Measuring accuracy Distance : less than +/- 1m Speed : +/-1cm/sec
Display 15inch LCD display at System console / LED display at Berth side display
Indicating interval 1 ~ 60 sec (selectable by every 1sec)
Printing items Distance, Speed, Date, Time, Print Script of LCD
Output (option) RS232C or RS422
Speed Alarm Max 99cm/sec (selectable by every 1cm/sec)
Ripping Alarm Max 9.9m (selectable by every 0.1m)
Power supply AC100V 50/60Hz
Power consumption Less than 350VA including 2 x Laser sensor (12VA), Berth side display (12VA)
Laser emission Safety Class 1 (JIS C 6802)