Thứ Hai, 17 tháng 9, 2018

PR-6000 Tokyo KeiKi Vietnam

PR-6000 Tokyo KeiKi Vietnam, PR-6000 Tokyo KeiKi Viet nam , PR-6000 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam

This high-grade autopilot model was designed with three fundamental concepts in mind: expanding and strengthening helm functions, thorough safety considerations, and improved reliability and more intelligent maintenance functions.
  • IBS (Integrated Bridge System) compatibility
  • Improved interface
  • Complete range of controls
  • Compatible with a variety of steering systems
  • Safety considerations designed in
  • Standard compatibility with digital output gyros

PR-2000 Tokyo KeiKi Vietnam

PR-2000 Tokyo KeiKi VietnamPR-2000 Tokyo KeiKi Viet namPR-2000 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam

This best-selling model has been installed in over 15,000 small and medium vessels including fishing boats, coastal craft, and merchant ships, and is renowned for its stable performance and ease of use.
  • Designed for operational simplicity
  • More affordable, with improved course holding ability
  • Variety of system configurations (stand-alone model, GYLOT model, console model)
  • Compatible with a variety of steering systems
 "GYLOT" is a registered trademark of TOKYO KEIKI.

TMG-30 Tokyo KeiKi Vietnam

TMG-30 Tokyo KeiKi VietnamTMG-30 Tokyo KeiKi Viet namTMG-30 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam



Optimal machine operation based on gyrocompass attitude navigational information
In excavation of complicated and interconnected underground tunnels for subways, water lines, and communication and power lines, accuracy in following plan lines is vital. Development of the new TMG-30 Series attitude sensing system for tunnel boring machinery is based on our experience on more than 1800 site applications and our expertise in advanced technology. The System's precision gyrocompass and servo-inclinometer offer real-time detection of azimuth angle, pitch & roll with stable attitude readouts. The small, lightweight and high precision, TMG-30 Series is a valuable aid in tunnel excavations, both large and small.

Features

  • Small size, high accuracy
    Compared to our previous model, the sensor unit is approx. 30% smaller and the controller and power supply are approx. 70% smaller. Static accuracy is ± 0.05 deg.
  • Real-time monitoring of machinery attitude
    Azimuth angle and pitch & roll can be displayed in real time, for continuous monitoring and accurate control of machinery movement.
  • Efficiency
    Unlike laser and lightwave systems, there is no need for time-wasting resetting.
  • Backup battery
    The backup battery assures continuous operation even in the event of a power supply failure.
  • Monitoring
    With the easy-to-read monitor, communication errors, and other information is at your fingertips.
  • System expansion
    Efficient excavation and accurate monitoring can be enhanced in combination with the TL300 Series Level sensing System and the Tellus Series Automated Position & Attitude-sensing System.

UFH-100 Tokyo KeiKi Vietnam

UFH-100 Tokyo KeiKi VietnamUFH-100 Tokyo KeiKi Viet namUFH-100 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam
 
looking for a highly accurate and reliable flow metering system? Check out the UFH-100!
Microwave level gauge is included as standard equipment!

UFH-100 flowmeter measures free surface flows of such fluids as...
Typical Applications 
・Supply water ・Agrigultural water
・River water ・Waste water
・process water ・industrial effuents

The TOKYO KEIKI UFH-100 ultrasonic flowmeter system for open channels employs the latest in ultrasonic and microwave technology.
Utilizing our wealth of know-how and technical expertise, the UFH-100 system combines an ultrasonic flow rate meter with a microwave level gauge to provide accurate and stable flowmeasurements.
It is applicable for liquids with free surfaces such as agricultural water, river water, waste water and industrial effluents.

Specifications
Measurable liquidApplications: agricultural water, river water, process water, industrial effluents, etc.
Water temperature: 0~40℃ /Turbidity: ≤ 10000 mg/L (degree)
Measurement water channelWater channel width: 0.3~20m (circular water channels φ0.3~5m)
Needed channel straight run: standard - upstream ≥ 10B, downstream ≥ 5B
(B: water channel width, pipe diameter in case of circular water channel)
Measurement principleFlow: flow velocity x channel cross sectional area (water level) computation method
Flow velocity: ultrasonic pulse transit time difference method
Water level s from existing or any 2 wire level gauge (DC 4~20mA can be utilized
Measurement rangeFlow: 0~full water level flowFlow velocity: 0~10m/sWater level: 0~10m
Output signalsFlow: 4~20 mA DC (allowable load resistance within 750Ω) with arrester element
Flow Pulse: Capacity AC 3~250V / DC 3~125V
Flow velocity: 4~20 mA DC (option: allowable load resistance within 750Ω)
Water level 4~20 mA DC (option: allowable load resistance within 750Ω)
AccuracyFlow     Forward flow: less than ±3% of full scale
            Reverse flow: not specified as it depends on channel structure
(+/- 10mm or better accuracy for level gauge required.)
Alarm relay outputWater level measurement failure, flow velocity measurement failure
Display16 digit x 16 digit LCD display (with backlight)
Flow value: max. 6 digits (incl. comma, decimal point)
Water level: max. 6 digits (incl. m unit, comma and decimal point)
Flow velocity: max. 6 digits (including m/s unit, comma and decimal point)
Operation status indication 
Power sourceAC90V - 132V (50/60 ±2Hz)   Standard
AC180V - 250V (50/60 ±2Hz)   (Option)
Power consumptionAC100V approx. 30VA
AC240V approx. 40VA
Ambient temperature -10C degree ~ 50C degree
Ambient humidityLess than 90% RH (non-condensation)
Main unit configurationWall mount type IP5X (IEC60529 / dust proof)
WeightApprox. 10 kg (approx. 11 kg with ultrasonic water level gauge)

UFP-20 Tokyo KeiKi Vietnam

UFP-20 Tokyo KeiKi VietnamUFP-20 Tokyo KeiKi Viet namUFP-20 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam


Portable Ultrasonic Flowmeter UFP-20 Now Comes, Versatility ! Functionality ! Reliability !
The Portable Ultrasonic Flowmeter UFP-20, based on the same, ergonomically advanced design so popular in the UFP-10, features significant size reduction. The result is a portable ultrasonic flowmeter that meets next-generation standards.The UFP-20's single-handed portability means difficult and challenging jobs located in narrow or high places can now be performed safely and easily.

The flowmeter includes a thickness measurement function and can effectively measure the sound velocity of fluids. Measurement data can be printed, logged or transferred to a computer which can assist data collection and analysis.

Light Weight - 1.4 kg
Wide Display and Easy Operation
Pipe Range : 13 - 5000 mm
Transducer can use : -20 - +120C degree
Weather-proof structure : IP65




Multi-Flow Measurement Function
Easy configurable for 2-Channel or 2-Path measurement



2-channel:Multi-flow measurement

2-path:Higher Stability




Energy Meter Function
Energy flow rate measurements with Pt100 RTD option.


Receiving-Echo Monitor Function
Visual confirmation that receiving echo is “good”.

Weather-proof structure IP65
IP65 rating maintained even during measurement.

USB Memory Data Transfer
Logged data and site conditions can be storaged into internal memory.


Language selection
You can choose
English, French, German, Italian,Japanese, Portuguese, Russian, Spanish, and Turkish.



Example of flowmeter or massmeter basic system




Example of heatmeter basic system



UFH-100 Tokyo KeiKi Vietnam

UFH-100 Tokyo KeiKi VietnamUFH-100 Tokyo KeiKi Viet namUFH-100 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam

looking for a highly accurate and reliable flow metering system? Check out the UFH-100!
Microwave level gauge is included as standard equipment!

UFH-100 flowmeter measures free surface flows of such fluids as...
Typical Applications 
・Supply water ・Agrigultural water
・River water ・Waste water
・process water ・industrial effuents

The TOKYO KEIKI UFH-100 ultrasonic flowmeter system for open channels employs the latest in ultrasonic and microwave technology.
Utilizing our wealth of know-how and technical expertise, the UFH-100 system combines an ultrasonic flow rate meter with a microwave level gauge to provide accurate and stable flowmeasurements.
It is applicable for liquids with free surfaces such as agricultural water, river water, waste water and industrial effluents.

Specifications
Measurable liquid
Applications: agricultural water, river water, process water, industrial effluents, etc.
Water temperature: 0~40℃ /Turbidity: ≤ 10000 mg/L (degree)

Measurement water channel
Water channel width: 0.3~20m (circular water channels φ0.3~5m)
Needed channel straight run: standard - upstream ≥ 10B, downstream ≥ 5B
(B: water channel width, pipe diameter in case of circular water channel)

Measurement principle
Flow: flow velocity x channel cross sectional area (water level) computation method
Flow velocity: ultrasonic pulse transit time difference method
Water level s from existing or any 2 wire level gauge (DC 4~20mA can be utilized

Measurement range
Flow: 0~full water level flow
Flow velocity: 0~10m/s
Water level: 0~10m
Output signals
Flow: 4~20 mA DC (allowable load resistance within 750Ω) with arrester element
Flow Pulse: Capacity AC 3~250V / DC 3~125V
Flow velocity: 4~20 mA DC (option: allowable load resistance within 750Ω)
Water level 4~20 mA DC (option: allowable load resistance within 750Ω)

Accuracy
Flow     Forward flow: less than ±3% of full scale
            Reverse flow: not specified as it depends on channel structure
(+/- 10mm or better accuracy for level gauge required.)

Alarm relay output
Water level measurement failure, flow velocity measurement failure
Display
16 digit x 16 digit LCD display (with backlight)
Flow value: max. 6 digits (incl. comma, decimal point)
Water level: max. 6 digits (incl. m unit, comma and decimal point)
Flow velocity: max. 6 digits (including m/s unit, comma and decimal point)
Operation status indication 

Power source
AC90V - 132V (50/60 ±2Hz)   Standard
AC180V - 250V (50/60 ±2Hz)   (Option)

Power consumption
AC100V approx. 30VA
AC240V approx. 40VA

Ambient temperature
 -10C degree ~ 50C degree
Ambient humidity
Less than 90% RH (non-condensation)
Main unit configuration
Wall mount type IP5X (IEC60529 / dust proof)
Weight
Approx. 10 kg (approx. 11 kg with ultrasonic water level gauge)

Chủ Nhật, 16 tháng 9, 2018


UVH-2000 Tokyo KeiKi Vietnam,  UVH-2000 Tokyo KeiKi Viet nam ,  UVH-2000 Tokyo KeiKi
TOKYO-KEIKI VIETNAM , TOKYO-KEIKI VIETNAM Vietnam

Doppler Technology For Sewage, Wastewater or Industrial Effluents.
Accurate and stable flow measurements for open channels with Ultrasonic Pulse Doppler technology. The UVH-2000 measures velocity of flow which contain fine particles or slurries such as sewage and wastewater

The UVH-2000 flowmeter incorporates a velocity meter and level gauge to measure flows through pipes or open channels with free water surfaces of sewage, wastewater, industrial and other effluents containing fine particles, sludge or fine bubbles.
The UVH-2000 velocity meter employs Pulse Doppler technology, which provides flow velocities at multi-points on the ultrasound beam and an ultrasonic level gauge, which provides non-contact liquid level measurement.
The UVH-2000 is suitable for applications such as maintenance and flow management of industrial effluents, public utilities, sewage plants and sewage systems.

Specifications
Measurement MethodFlow velocity: Ultrasonic Pulse Doppler
Fluid level: Ultrasonic Pulse Transit Time
FluidsSewage, waste water, Industrial Effluents, or other Fluids with suspended matters Fluids or small bubbles which reflect ultrasonic waves with a free water surface (turbidity, approx. 60~50,000 mg/L)
Fluid Temperature0 ~ +40℃
Applicable open ChannelOpen channels: Rectangular, Circular, etc. Closed Conduit
 Dimensions of Circular type: Inner diameter φ250 ~ 5000mm
 Dimensions of Rectangular. Width 250 ~ 5000mm
Measurement RangeFlow velocity: -5 ~ +5 m/s
Water level: 0 ~ 5000 mm
Measurement AccuracyWithin ±3% of Full Scale
Main Unit DisplayLCD: 16 x 16 Characters
Displayed items: Flow rate/ Totalized Flow/ Flow Velocity/ Water Level,
                 Measurement Units. and Functions (at configuration) 
Power SupplyAC90 ~ 132V, 180 ~ 264V, DC19 ~ 29V
Power ConsumptionApprox. 38VA (AC100V), approx. 58VA (AC240), Approx. 24W (DC24V) 
Output SignalsFlow Rate: 4 ~ 20 mA   DC (allowable resistance: less than 750Ω)
Totalized Flow: Photo MOS Relay (Insulated)
Flow Velocity: 4 ~ 20 mA    DC (allowable resistance: less than 750Ω)
Water Level: 4 ~ 20 mA    DC (allowable resistance: less than 750Ω)
Flow Velocity Meter Malfunction Warning: Photo MOS Relay (Insulated)
Level Gauge Malfunction Warning: Photo MOS Relay (Insulated)
Forward Flow Reverse Flow Discrimination: Photo MOS Relay (Insulated)
Ambient Temperature -10 ~ +50℃.
Ambient HumidityLess than 90% RH (non-condensation)
Main Unit WeightApprox. 16kg
Main Unit DimensionsW332 x H520 x D170 (including mounting bracket)
OptionsMulti Path Flow Velocity Measurement: Max. 4 Paths
Level Measurement: Radar Level Gauge